Ordering CodeHSM-1000
Power Mode
Resolution0.1% of Full Scale
Energy Mode
Resolution0.1 % of Full Scale
Pulse repetition rate Range1 kHz – 1 MHz
Power Probe Mode (FIT-H)
ResolutionN.A.
General Operating Characteristics
Sensor CompatibilityBLINK HS
Storage Temperature Range-20 / +70 °C
Operating Temperature Range+5 / +40 °C
Relative Humidity Range20 / 80 %
PC connectivityEthernet 100/1 G
Sensor Head connectivityHirose IX - High Speed connector
Selectable WavelengthsUp to 16 wavelengths
Dimensions182 L x 162 W x 57 H (mm)
Weight740 g
DisplayN.A.
BatteryN.A.
Battery charge timeN.A.
Battery run timeN.A.
Supplied battery charger12V 24W AC/DC Power Supply
Electronics Characteristics
ADC sampling rate500 Msamples/s
ADC resolution14 bit
Analog OutputN.A.
Analog Output AccuracyN.A.
Notes
a) For any Full Scale
 
Options
Catégorie : Ordering code: HSM-1000
Lire termes et conditions

Description

High Speed Meter (HSM)

HSM is a High Speed Meter specifically developed to connect High Speed Sensor Blink HS to PC via Ethernet, to acquire and display data of laser pulse trains and perform statistics  on many laser parameters such as energy, power, repetition rate, peak energy.

HSM is able to sample data with a sampling rate up to 500 Msamples/s to provide a precise energy measurement of each single ultrashort pulse up to 1 MHz repetition rate. It is suitable for ultrashort pulsed lasers down to femtosecond pulse duration.

HSM can work according to two different modes, the “Oscilloscope mode” allowing to display on the PC the acquired laser pulse train and the “In Time Parameters” where the user can monitor the behavior of many different parameters of the acquired laser pulse train such as the energy of each pulse, power, repetition rat and peak power. A user friendly Graphic User Interface (Blink-HS-GUI) is supplied with HSM to easily display data on PC using the two modes. External power supply for HSM is 12 V with 2 A maximum current. BlinkHS sensor is connected to HSM via a specific microwave cable supplied with the sensor. Measurement resolution of HSM (%, full scale) is 0.1% with measurement accuracy of +- 1%. Trigger IN and trigger OUT SMA connectors are available on the HSM front panel to allow triggering of HSM measurements from an external trigger source or to provide an internal  trigger signal respectively.

Informations complémentaires

Sign up for our Newsletter and receive the latest news from LaserPoint




Choose the area of your interest:*

Subscribe the newsletter*