| Power Mode | |
| Max. Average Power | 30 W |
| Max. Average Power (1) | 45 W |
| Min. Power | 25 mW |
| Power Resolution | 1 mW |
| Noise Equivalent Power (NEP) | 1 mW |
| Response Time (0-90%) | 1.5 sec |
| Power Calibration Uncertainty | ± 3% |
| Power Linearity (2) | ± 1.5% |
| Single Shot Energy Mode | |
| Max. Energy (with 100 ms pulse) | 45 J |
| Min. Energy | 100 mJ |
| Energy Resolution | 1 mJ |
| Energy Calibration Uncertainty | ± 5% |
| Absorber Specs | |
| Aperture | 18 mm |
| Type | DIF |
| Absorber Spectral Range | 0.2 - 2.1 µm |
| Calibration Spectral Range | 0.532 µm; 1.064 µm |
| Max Power Density (3) | 160 kW/cm² |
| Max Energy Density (3) | 5ms pulse width: 1200 J/cm² 10µs pulse width: 22 J/cm² 10ns pulse width: 6.5 J/cm² |
| General Characteristics | |
| Cooling | Convection |
| Weight | 0.6 kg |
| Dimension | 75 x 75 x 52 mm |
| Cable length - connector | 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) |
| Stand and Post | Light Duty Stand |
| Notes | |
| (1). 2 minutes max (2). Detector centrally irradiated @50% of useful surface. (3). Damage thresholds also depend on power level. Please see damage graphs for more details. | |
Configurer les options